Easyzone

THERMOSTAT

Airzone Blueface

Colour graphic interface with capacitive screen for controlling zones in Airzone systems. Powered by main control board. Finished in steel and glass. Available in white or black. Functionalities: Available in Spanish, English, French, Italian, German and Portuguese. Control of temperature, operating mode (Master thermostat) and system speed (Master thermostat and fancoil installations). Room temperature and relative humidity measurement of the zone Configuration stages control (air, radiant or combined). Eco-Adapt saving and Sleep function. Temperature and mode time schedules. Remote access to other zones of the system. Weather forecast and AC unit consumption (optional).

236,00 €
AZCE6BLUEFACECB
Airzone Blueface White
Add to cart
AZCE6BLUEFACECN
Airzone Blueface Black
Add to cart
Features

Eco-Adapt

Energy efficiency at a sigle touch. Select the energy efficiency level for your system and it will command the AC unit accordingly.

Access to any zone

From a Blueface controller any other zone or even all the system can be controlled at once. There is no need to phically move to each zone.

Weather forecast

Get the information about it will rain, freeze or the sun will shine. Any system connected to internet throuth the Webserver Cloud, it will retrieve and display the weather forecast information .

Time schedules

Program it to get the most of it all. Easyly set any event at any time

Temperature control

Select your comfort temperature, independant from the other zones or set the zone to off
FAQ

Check our answers for the most common questions about our products.

Related support articles
Airzone operating modes
Airzone operating modes
The operating mode indicates the mode in which the system is working. The available modes are as follows:

Stop: The air conditioning system will shut down regardless of the status of the rest of the zones. In addition, all terminal elements (grilles, dampers, etc.) will be closed.

Fan: In this operating mode, the system only operates with the air conditioning unit in fan mode when any of the zones associated to the system is generating demand (set-point temp. < room temp.).

Cooling: In this operating mode, the system only operates with the air conditioning unit in cooling mode when any of the zones associated to the system is generating demand (set-point temp. < room temp.).

Heating: In this operating mode, the system only operates with the air conditioning unit in heating mode when any of the zones associated to the system is generating demand (set-point temp. > room temp.).

Dry: In this operating mode, the system only operates with the air conditioning unit in dry mode when any of the zones associated to the system is generating demand (set-point temp. < room temp.). 
The wired thermostat displays Error 1 - Communications failure between thermostat and main control board
The wired thermostat displays Error 1 - Communications failure between thermostat and main control board
Check whether the error appears on all thermostats. If so, check that the systemÕs main control board is operating properly. To do so, check the behavior of all its self-diagnostic LEDs and ensure they are as set out in the technical fact sheet (  Easyzone main controller - Flexa 3.0 - Product Data Sheet  ).

If the behavior of the LEDs is appropriate, check that the polarity of the connectors of the main control board and thermostat is correct. The wiring can be consulted in the Assembly and Connection section of the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).

If the wiring is correct and the problem persists, check the voltage between the poles (A /-) and (B /-). The voltage should be between 0.5 Vdc and 2 Vdc and the two measurements should be similar (be balanced); in other words, if the voltage of A/- is 0.9 Vdc, the voltage of B/- may vary between 0.8 Vdc and 1.0 Vdc. If the voltages are not within these ranges, there is a problem in the wiring or one of the parts is defective. Get in touch with the Technical Department (  Open a new ticket  ).

If the voltages are correct, restart the zone and reassociate it to the system ( How can I reset a zone equipped with a Blueface thermostat when it displays Error 1?  ).

If the problem is not solved, restart the entire system and reassociate it ( How do I reset the entire system?  ).

Note: Take into account that this error may appear on the thermostats if the system is restarted. This message should disappear in approximately 30 seconds once the restart has been completed.
How can I reset a zone equipped with a Think or Blueface thermostat?
How can I reset a zone equipped with a Think or Blueface thermostat?
Follow the steps below to reset a zone: Access the Zone settings menu and then access the Reset thermostat parameter. Select Yes and the thermostat will be set up with its default factory settings (see the section entitled Zone Advanced Settings in the installation manual:   Easyzone main controller - Flexa 3.0 - Installation manual  ).
How can I reset a zone equipped with a Think or Blueface thermostat?
How can I reset a zone equipped with a Think or Blueface thermostat?
Follow the steps below to reset a zone: Access the Zone settings menu and then access the Reset thermostat parameter. Select Yes and the thermostat will be set up with its default factory settings (see the section entitled Zone Advanced Settings in the installation manual:   Easyzone main controller - Flexa 3.0 - Installation manual  ).
The thermostat displays a screen showing "A" for Airzone frequently and restarts
The thermostat displays a screen showing "A" for Airzone frequently and restarts
If your Blueface thermostat frequently displays an ""A"" for Airzone on the screen, it means that it is being reset. Proceed as follows:

Check that the thermostat's power feed is correct. To do so, measure the voltage between the positive and negative poles in the base of the thermostat (removing the thermostat), and also at the system's main control board connection terminal (after connecting the thermostat). In both cases, the voltage should be approximately 12 Vdc. Voltages of less than 11 Vdc indicate there is some kind of problem.

If the voltage is not correct, check the polarity of all the connectors on both the thermostats and the main control board. Check that there are no loose wires making a false contact with another wire.

If all the wiring is correct, replace the thermostat with another one in the installation and check what happens with the thermostat that was resetting itself in its new location and what happens with the thermostat that operated properly in its new location:
- If the thermostat suspected of suffering a failure continues to reset itself and the thermostat that initially operated well continues operating well, the problem resides in the thermostat. Get in touch with Airzone to replace the part.
- If the problem is now transferred to the other thermostat, the problem resides in the connection base or the wire. Replace that zone's wiring and reconnect the thermostat.
Basic mode/Advanced mode
Basic mode/Advanced mode
This is a zone settings parameter. By default, a thermostat has an Advanced functionality which allows the user to access all the parameters available. If the Basic settings are chosen, the user will only will have access to:

- Zone ON/OFF.
- Set-point temperature.

Other parameters like the operating mode cannot be accessed from Basic mode.

For further information, see the section entitled System advanced settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
Which is my installation's master thermostat?
Which is my installation's master thermostat?
If your thermostat is a Blueface thermostat, the installation's master thermostat will display the mode icon (top left-hand corner) in white, while the installation's other thermostats will display it in grey.

If it is a Think thermostat, the installation's master thermostat allows the mode to be changed by pressing on the settings button (image of button). If the menu appears which allows you to change the installation mode after pressing this button, then that is the master thermostat.
The thermostat does not measure the temperature well
The thermostat does not measure the temperature well
Check whether your thermostat meets all the location requirements recommended by Airzone:
1. There is no direct sunlight on the thermostat.
2. The thermostat is located away from draughty areas.
3. The thermostat is not placed above a heat source.
4. The thermostat is placed on the wall at the proper height.

If all these requirements are met and a temperature deviation is still detected on the thermostat, it can be adjusted from the Settings menu. Airzone system thermostats are equipped with an Offset parameter which allows the room temperature to be adjusted. Access your thermostat's Advanced settings parameters and adjust the Offset parameter to your needs.

For further information on this parameter, see the section entitled Zone Advanced Settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
Where can I find the settings menu?
Where can I find the settings menu?
You can find all the information on thermostat menus in TSXXX.
A Blueface thermostat displays Low battery
A Blueface thermostat displays Low battery
If a Blueface thermostat displays Low battery, it is because one of the Lite thermostats in the installation has a battery that is about to go flat. Press on the words ""Low battery"" and the zone having the problem will be displayed.

Follow the instructions in the following video to replace the battery: (  Replace the battery ).
Zone 0 appears on the thermostat when I connect it
Zone 0 appears on the thermostat when I connect it
If Zone 0 is displayed when your thermostat is connected and it is not possible to move forward from this screen, first check the thermostat's connection (image 1). Ensure that the wires are making good contact and are not loose. To do so, tug on them gently and ensure they are not released.

If the thermostat's connection is satisfactory, check that the bus's connection to the main control board is also correct (image 2). Check the polarity and that the wires are making good contact with the terminal connection.

If the connections are correct, proceed according to   The wired thermostat displays Error 1 - Communications failure between thermostat and main control board  , since the error is identical: there are no communications between the thermostat and the system's main control board.
The thermostat cannot be switched on
The thermostat cannot be switched on
If it is a wired thermostat, check the following:

1. Check that the power feed voltage is 12 Vdc.
2. Check the polarity of the thermostat's connectors.

If it is a wireless thermostat, check the following:

1. Check that the battery is correctly housed in the thermostat and with the right polarity.
2. Replace the thermostat's battery.

If the problem persists, see: ( My thermostat cannot be switched on  ).
What is the user menu and what is the installation menu?
What is the user menu and what is the installation menu?
There are three different menus in Blueface thermostats:

- User settings menu: Accessed by pressing (menu icon). It allows you to control and change basic functionalities.
- Zone settings menu: Accessed by pressing (settings icon). It allows you to change zone settings.
- Advanced settings menu: Accessed by pressing and holding (settings icon). It allows you to change Advanced settings parameters.

There are two different menus in Think thermostats:

- Parameter settings menu: Accessed by pressing (menu icon). It allows you to control basic parameters like mode, sleep, etc.
- Advanced settings menu: Accessed by pressing and holding (Airzone icon). It allows you to change advanced settings parameters.
How do I associate a thermostat?
How do I associate a thermostat?
The association varies depending on the thermostat:
- Blueface Thermostat: see   A Lite thermostat blinks red  .
- Wired Think Thermostat: see   I manage to associate the webserver to the router, but it still does not operate  .
- Wired Lite Thermostat: see   The grilles never close although the system operates properly  .
- Wireless Think Thermostat: see   How do I associate a wireless Think thermostat?  .
- Wireless Lite Thermostat: see   How do I associate a wireless Lite thermostat?  .
This information can also be found in your system's installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ). 
My thermostat cannot be switched on
My thermostat cannot be switched on
If your thermostat cannot be switched on, see the following links depending on of the type of thermostat:

- Blueface Thermostat:   Power does not reach a wired thermostat  .
- Wired Think Thermostat:   Power does not reach a wired thermostat  .
- Wired Lite Thermostat:   Power does not reach a wired thermostat  .
- Wireless Think Thermostat:   The wireless Think thermostat does not do anything  .
- Wireless Lite Thermostat:   The wireless Lite thermostat does not do anything  .
What are my thermostat's Control stages?
What are my thermostat's Control stages?
Control stages allow you to enable or disable cooling or heating air for each zone. Take into account that if a zone's stage is disabled, said zone will not generate demand and its damper will not open.

For further information on control stages, see the section entitled Zone Advanced Settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
Set up my thermostat as the installation's master thermostat
Set up my thermostat as the installation's master thermostat
In order to set up one of the installation's thermostats as the master thermostat, access the Thermostat settings parameter in the Zone parameters menu of the settings menu.

For further information, see the section entitled System Advanced Settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
My thermostat displays Error 5
My thermostat displays Error 5
A thermostat displaying Error 5 indicates it does not have a temperature sensor or is in an open circuit. The zone therefore loses the room temperature measurement. This leads to the zone being disabled for generating demand.

To confirm that it is not a part error, it should first be checked that no zones have been cross-labeled or incorrectly set. To do so, it is advisable to follow the procedure below:

Restart the zone and reassociate it to the system ( How can I reset a zone equipped with a Lite thermostat?  ).

If the problem is not solved, restart the entire system and reassociate it ( How do I reset the entire system?  ).

If the thermostat still displays Error 5 after these steps, the thermostat is faulty and should be replaced. Get in touch with the Airzone Technical Department (  Open a new ticket  ).
My thermostat displays Error 11
My thermostat displays Error 11
Error 11 warns about a communications failure between the Airzone AC unit gateway and the indoor unit. The system loses communication with the AC unit and will therefore open all its zones and disable control from the system's thermostats, thus allowing the AC unit to operate from the manufacturer's thermostat.

First check that the air conditioning unit has power. Check that the AC unit's thermostat is switched on. If not, switch on the air conditioning unit and the error will disappear after about a minute.

If the problem persists, check whether the AC unit operates properly independently of the system. To do so, disconnect the AC unit from the Airzone system and activate the unit from the AC unit's thermostat. If the AC unit does not operate independently of the Airzone system, get in touch with its manufacturer.

If the AC unit operates properly, continue with the checks to be found at: ( My thermostat displays Error 9  ).
Why does STOP appear on my thermostat's screen?
Why does STOP appear on my thermostat's screen?
The STOP mode shuts down the entire the Airzone system. If you need further information about Airzone operating modes, see the following link: ( Airzone operating modes  ).
The master thermostat is switched off and the system does not shut down
The master thermostat is switched off and the system does not shut down
The master thermostat controls the installation's operating mode. If you have any doubts about Airzone's operating modes, see: ( Airzone operating modes  ).

Besides the system's mode, the master thermostat controls your zone's air conditioning. Demand/no demand of the zone is controlled by switching the thermostat on/off, but not of the entire system.

If wish to switch off the entire system, you can do so through: Remote zones->All the zones->Off (consult the user manual) or through the STOP mode.
My thermostat displays Error 8 (I have wireless Lite thermostat)
My thermostat displays Error 8 (I have wireless Lite thermostat)
Error 8 indicates that a thermostat has lost communications with the system. The zone loses the room temperature measurement of an associated Lite thermostat, leaving the zone disabled to generate demand. Check from your Blueface thermostat whether the Lite thermostat has lost communications.

If your installation is equipped with wired Lite thermostats see: ( My thermostat displays Error 8 (I have wired Lite thermostat)  ).

If your installation is equipped with wireless Lite thermostats, follow the instructions below:

Check the battery's status and, if in doubt, replace it with a new battery ( My thermostat displays Error 8 (I have wireless Lite thermostat)  ).

Check whether the Lite thermostat in question has the microswitch that corresponds to the associated zone selected. If not, activate it by pulling up the tab to the desired value. Remember that, in order to associate wireless devices, you should first open the wireless association module either through the SW1 button on the main control board or from any thermostat in the Wireless module parameter of the System advanced settings, zone parameters.

Remember: Should it be necessary to change the zone number, first reset the thermostat and initiate the association sequence ( How can I reset a zone equipped with a Lite thermostat?  ).
The thermostat does not measure the humidity well
The thermostat does not measure the humidity well
Check whether your thermostat meets all the location requirements recommended by Airzone:
1. There is no direct sunlight on the thermostat.
2. The thermostat is located away from draughty areas.
3. The thermostat is not placed above a heat source.
4. The thermostat is placed on the wall at the proper height.

If all these requirements are met and the thermostat still displays an incorrect measurement, see the following link: ( There is a deviation in my thermostat's humidity measurement  ).
I cannot change the thermostat's mode
I cannot change the thermostat's mode
In order the change the Airzone system's operating mode, you must access the installation's master thermostat and press the icon located on the top left-hand corner.

You can consult the behavior of each mode at the following link ( Airzone operating modes  ).

If you press on the icon but nothing happens (no selection menu opens), check whether the thermostat is set up as the master thermostat or whether the installation's master thermostat is in another zone. For further information on the installation's master thermostat, see the following link: ( Which is my installation's master thermostat?  ).

If you are sure that the thermostat you are trying to access is the master thermostat, check whether it has been set up in Basic mode. You can check this at the following link: ( Basic mode/Advanced mode  ).
The dampers do not open, the system always displays STOP
The dampers do not open, the system always displays STOP
First check whether the thermostat allows you to access the change mode screen. If not, locate the installation's master thermostat ( Which is my installation's master thermostat?  ).

If you are indeed accessing from the master thermostat and the problem is that it selects a mode other than STOP and the system automatically reverts back to STOP, the problem could be in the main control board. Check whether there is a bridge at connector J14 (ALAR) in the main control board and that it is actually being short-circuited (check with a multimeter). If is not, short circuit the two poles of connector J14.
There is a deviation in the room temperature reading
There is a deviation in the room temperature reading
Airzone system thermostats are equipped with an Offset parameter which allows the room temperature to be adjusted. Access your thermostat's Advanced settings parameters and adjust the Offset parameter to your needs.

For further information on this parameter, see the section entitled Zone Advanced Settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
The thermostat is at a distance from the room's habitable zone and the temperature difference between both zones generates discomfort
The thermostat is at a distance from the room's habitable zone and the temperature difference between both zones generates discomfort
Airzone system thermostats are equipped with an Offset parameter which allows the room temperature to be adjusted. Access your thermostat's Advanced settings parameters and adjust the Offset parameter to your needs.

For further information on this parameter, see the section entitled Zone Advanced Settings in the installation manual (  Easyzone main controller - Flexa 3.0 - Installation manual  ).
There is a deviation in my thermostat's humidity measurement
There is a deviation in my thermostat's humidity measurement
The relative humidity measured by the thermostat is highly related to the surrounding conditions. The thermostat's location might be causing a deviation in the room temperature measurement and this in turn leads to a deviation in the humidity measurement.

Check the thermostat's room temperature measurement, using a properly calibrated thermometer to do so. If the measurement is incorrect, see the following link ( The thermostat is at a distance from the room's habitable zone and the temperature difference between both zones generates discomfort  ).

If the humidity measurement continues to be wrong, check whether your thermostat is properly installed. See: ( The thermostat does not measure the humidity well  ).
The thermostat displays "Zone N" on the screen
The thermostat displays "Zone N" on the screen
If a thermostat displays the word "Zone" on screen and a number below it with two arrows, it means that it is waiting for a control zone to be selected for that thermostat. (Airzone Blueface and Airzone Think Thermostat Initial Settings in   Easyzone main controller - Flexa 3.0 - Installation manual  )
How do I set up a thermostat as the installation's master thermostat?
How do I set up a thermostat as the installation's master thermostat?
The installation's master thermostat is the thermostat which controls the way the AC unit operates (cooling, heating, fan, etc.).

The installation's master thermostat can be chosen during the zone association process (see Airzone Blueface and Airzone Think Thermostat Initial Settings in the installation manual). This option can also be changed subsequently by selecting another thermostat as the master thermostat.

The system must first be left without a master thermostat so a new master thermostat can be selected for the installation. If there is already a master thermostat, access the Zone advanced settings menu and then chose ZONE in the Thermostat settings parameter to do so (see System Advanced Settings in   Easyzone main controller - Flexa 3.0 - Installation manual  ).

The next step consists of selecting a new master thermostat for the installation. To do so, access the thermostat's Zone advanced settings menu and select MASTER.
How are names assigned to the different zones of my home or office?
How are names assigned to the different zones of my home or office?
You can assign names to the different zones through the Blueface thermostat or the Airzone Cloud Webserver.

If you wish to change the names of your installation's zones through a Blueface thermostat, follow the instructions you can find the in the section entitled Handling Blueface Thermostats in your system's user manual (  Easyzone user manual  ).

If you wish to change the names of the zones through the Airzone Cloud, follow the instructions you can find the in the section entitled Settings in your webserver manual (  Airzone Webserver Cloud - User Manual  ).

In any event, you can view the videos on how to use Blueface thermostats and the webserver to perform this and other actions.
How are time schedules programmed by zones?
How are time schedules programmed by zones?
The Airzone system allows time schedules to be programmed to switch on/off, change the temperature, etc. of your zones at the time you wish. You can program time schedules through the Blueface thermostat or the Airzone Cloud Webserver.

If you wish to program time schedules through a Blueface thermostat, follow the instructions you can find in the section entitled Handling Blueface Thermostats in your system's user manual (  Easyzone user manual  ).

If you wish to program time schedules through the Airzone Cloud, follow the instructions you can find in the section entitled Time Schedules in your webserver manual (  Airzone Webserver Cloud - User Manual  ).

In any event, you can view the videos on how to use Blueface thermostats and the webserver to perform this and other actions.
The thermostat's back cover is broken
The thermostat's back cover is broken
If the thermostat's back cover or any of its connections are broken, get in touch with the Technical Support Department for a replacement (  Open a new ticket  ).
Power does not reach a wired thermostat
Power does not reach a wired thermostat
If your thermostat is not switched on after connecting it to the system, first check the thermostat's connection (image 1). Ensure that the wires are making good contact and are not loose. To do so, tug on them gently and ensure they are not released.

If the thermostat's connection is satisfactory, check that the bus's connection to the main control board is also correct (image 2). Check the polarity and that the wires are making good contact with the terminal connection.

If the connections are correct, check whether 12 Vdc power reaches the thermostat. To do so, check that there is 12 Vdc at both connections between the red wire (+) and the black wire (-).

If no power reaches the thermostat, check whether it leaves the main control board. To do so, disconnect the main control board's bus connection terminal (image 2) and check whether there is voltage between the + and - connection terminals. If there are 12 Vdc, the problem resides in one of the terminal connections. If there is no voltage, the main control board has a power feed fault and you will have to get in touch with the Technical Support Department (  Open a new ticket  ).
What difference is there between mode and temperature programs?
What difference is there between mode and temperature programs?
A mode program selects the entire installation's operating mode: Cooling, heating, stop, etc.

A temperature program selects the temperature desired for a zone. It only affects the zone which has been programmed.
Country Site

It looks like you are visiting the global website from .
Since we don't provide service to your country from this site, please visit your local Airzone website.