Easyzone

MOTORIZED PLENUM

Airzone 6X200 mm - 02M

Standard motorized plenum with neck that mechanically adapts to the main ducted AC units of TOSHIBA. It includes a main board, circular dampers of 200 mm in diameter and communications gateway for a complete integration of the Airzone system. It does not require a bypass damper. It has a controlled mechanical ventilation (CMV) input allowing the use of the duct network to renew the air. Certified System by Eubac european norm. Check our selection chart to see all the available ranges, sizes and dampers.

1.643,00 €
AZEZ6TOSST02M6
Airzone 6X200 mm - 02M
Add to cart
Features

Leverage air-flows

Each of its 6 outlet includes an air-flow regulation mechanism to adapt each outlet to its requiremets

Factory done wiring

Get your jod done as fast as possible and avoid wiring and connection errors.

Fully isolated body

Protected againts drains, its construction and materials are selected to stand in humid ambiences

Frame adapted

Specifically designed to match each unit perfectly, with same fitting holes

Fresh air inlet

Combine fresh air and treated air and distribute it through the same ducts

Seamless integration

Develped in collaboration with IU manufacturers, our Communication gateways "speaks" the same language with the Indoor Unit providing a reliable communication
FAQ

Check our answers for the most common questions about our products.

Related support articles
The actuators of my dampers do not operate
The actuators of my dampers do not operate
If the associated damper does not operate after switching a zone on/off, run the following checks:

Check that the LEDs associated to the relevant actuator output light up when a zone's demand is switched on/off. For further information, see the main control board technical fact sheet (  Easyzone main controller - Flexa 3.0 - Product Data Sheet  ).

If the LEDs light up properly (green = opened, red = closed), the problem could reside in the actuator's wiring or in the actuator itself. To check whether the damper operates properly, connect it to the actuator output of another damper that is operating properly. If it operates properly, the problem is probably in the actuator output. Connect another damper to it to check if it operates. If it does not, the main control board has an actuator output that does not operate. If you have any free outputs, use one of them, otherwise you will have to replace the main control board.

If the damper still does not operate after connecting it to another output, the problem resides in the damper and it should be replaced.
When a zone is switched off, the motorized damper stays open
When a zone is switched off, the motorized damper stays open
If the damper associated to a zone does not close despite having switched off said zone, run the following checks:

Check that it is not the last zone to close. The system has a four-minute closure delay in the last zone. Once that time has elapsed, the zone will be closed. In the case of Easyzone, the last zone's closure involves the opening of all the zones.

Check concordance between thermostats and actuator outputs. To do so, switch on and generate demand in all the system's zones, checking that all the dampers remain open. Then switch off the zone in question and check that the damper of another zone has not been closed.

If the above has not happened, check that the zone number corresponds to the actuator output.

If it still does not close, there may be a malfunction in the actuator. Consult opening of actuators ( The actuators of my dampers do not operate  ).
A zone's damper does not open
A zone's damper does not open
If the damper associated to a zone does not open when an Airzone system zone is switched on, run the following checks:

Check that the Airzone system is set to an operating mode other than Stop and that the set-point temperatures generate demand. If you have any doubts about the behavior of the operating modes see ( Airzone operating modes  ).

Check concordance between thermostats and actuator outputs. To do so, switch off all zones and switch on the zone in question to generate demand. Check that the damper of another zone has not been opened. If this is the case, you must interchange the actuator outputs in the main control board.

If the problem has not been solved, check that the zone number corresponds to the actuator output.

If the problem persists after these checks, it could be due to:
- Zone settings. Check the zone's control stages ( What are my thermostat's Control stages?  ).
- The operation of the actuator. Consult opening of actuators ( The actuators of my dampers do not operate  ).
A zone's damper does not close
A zone's damper does not close
If the damper associated to a zone does not close despite having switched off said zone, run the following checks:

Check that it is not the last zone to close. The system has a four-minute closure delay in the last zone. Once that time has elapsed, the zone will be closed. In the case of Easyzone, the last zone's closure involves the opening of all the zones.

Check concordance between thermostats and actuator outputs. To do so, switch on and generate demand in all the system's zones, checking that all the dampers remain open. Then switch off the zone in question and check that the damper of another zone has not been closed.

If the above has not happened, check that the zone number corresponds to the actuator output.

If the problem persists after these checks, it could be due to:
- Zone settings. Check the zone's control stages ( What are my thermostat's Control stages?  ).
- The operation of the actuator. Consult opening of actuators ( The actuators of my dampers do not operate  ).
When I switch off a zone, the damper of that zone opens
When I switch off a zone, the damper of that zone opens
If the damper of a zone opens when said zone is switched off, it could be the case that the polarity of the actuator's output is not correct. (Red / +) and (Black / -). Check it.

If the polarity is correct, check whether the actuator operates properly ( The actuators of my dampers do not operate  ).

Take into account that in the Airzone Easyzone system the AC unit is switched off when all the zones are switched off and that all dampers are opened in four minutes ( The dampers open when I switch off all my system's zones  ).
When a zone is switched on, the damper of that zone closes
When a zone is switched on, the damper of that zone closes
If the damper of a zone closes when said zone is switched on and demand is generated in it, it could be the case that the polarity of the actuator's output is not correct. (Red / +) and (Black / -). Check it.

If the polarity is correct, check whether the actuator operates properly ( The actuators of my dampers do not operate  ).
My system's dampers do not open or close
My system's dampers do not open or close
If the dampers do not operate despite switching the system on (generating demand), check the following:

Take into account that the system has a four-minute closure delay in the last zone. Once that time has elapsed, the zone will be closed. In the case of Easyzone, the last zone's closure involves the opening of all the zones. The system is in Sleep mode and will therefore have the dampers open.

Check concordance between thermostats and actuator outputs. To do so, switch off all the zones and switch each zone on one by one, checking that the relevant dampers open.

If the problem persists after these checks, it could be due to:
- Zone settings. Check the zone's control stages ( What are my thermostat's Control stages?  ).
- The operation of the actuator. Consult opening of actuators ( The actuators of my dampers do not operate  ).
I have everything installed and associated. I switch on a zone and it does not operate
I have everything installed and associated. I switch on a zone and it does not operate
If the damper associated to a zone does not open when an Airzone system zone is switched on, run the following checks:

Check that the Airzone system is set to an operating mode other than Stop and that the set-point temperatures generate demand. If you have any doubts about the behavior of the operating modes see ( Airzone operating modes  ).

Check concordance between thermostats and actuator outputs. To do so, switch off all zones and switch on the zone in question to generate demand. Check that the damper of another zone has not been opened. If this is the case, you must interchange the actuator outputs in the main control board.

If the problem has not been solved, check that the zone number corresponds to the actuator output.

If the problem persists after these checks, it could be due to:
- Zone settings. Check the zone's control stages ( What are my thermostat's Control stages?  ).
- The operation of the actuator. Consult opening of actuators ( The actuators of my dampers do not operate  ).
The dampers open when I switch off all my system's zones
The dampers open when I switch off all my system's zones
The Airzone Easyzone system opens all the dampers when all zones are switched off. This protects against excessive pressures caused by AC units' maintenance cycles.
How do I change the damper associated to a zone equipped with a Think or Blueface thermostat?
How do I change the damper associated to a zone equipped with a Think or Blueface thermostat?
To change the damper associated to a zone, you first have to reset that zone. To do so, access the Zone settings menu and then access the Reset thermostat parameter. Select Yes and the thermostat will be set up with its default factory settings (see the section entitled Zone Advanced Settings in the installation manual:   Easyzone main controller - Flexa 3.0 - Installation manual  ).

Now you only have to associate the new thermostat and choose the desired zone. To do so, follow the instructions in the System Initial Settings section in the installation manual. (  Easyzone main controller - Flexa 3.0 - Installation manual  )
The grilles never close although the system operates properly
The grilles never close although the system operates properly
The grilles in each zone are always open. It is actually the dampers that open and close, which cannot be seen by the user.

Airzone motorized dampers are located in the plenum, which is coupled to the installation's indoor unit.
What are associated outputs?
What are associated outputs?
When a thermostat is associated to a zone, said thermostat goes on to control by default the damper having that zone number.

 Nevertheless, it is possible to control more than one damper from the same thermostat. The "Associated outputs" parameter is used to do this. This setting can be configured when the initial association is done or subsequently in the Zone advanced settings menu.